Honest Local HVAC Company Serving Wyoming, MI
GRmetro Heating & Cooling proudly provides prompt, personal, and professional services in Wyoming, MI because that’s the best way to achieve energy efficiency and long-lasting results. We’ve been in the industry for 30 years, and we’re not planning on going anywhere. Our services speak for ourselves and our professionals are more than qualified to get any of the following work done. If you or anyone you know needs help with their air conditioner, heater, or indoor air quality system, there should be only one number you call. That’s ours!
Witness high-quality, professional service that keeps customers coming back when you call our team for your HVAC services. Contact us today!
Air Conditioning
Do you need help with your air conditioning? Perhaps you need a central air conditioner repair or the entire replacement of your heat pump system? We’ve got you covered. We take the necessary steps to ensure that every job we perform is done to your standards and up to code. No matter how unique your home situation is, or how large the system might be, we can take care of it.
Heating
Many homes in Wyoming, MI have unique heating setups. Some homeowners who call us are looking for repairs to be performed on their dual fuel systems, furnaces, or other niche heating systems. Others are looking to install a brand-new system or have their old one replaced entirely. Regardless of what you’re looking for, we can help! Let us handle all your heating needs!
Heat Pumps
Heat pumps are all the rage these days, and for good reason! They provide quality heating and cooling for homes in Wyoming, MI and they do so at an affordable price. Heat pump repairs can be done effectively and quickly when you call us. We’ll even upgrade your thermostat when we replace your heat pump system, to ensure you get the quality comfort and control that you deserve!
Indoor Air Quality
We provide installation, replacement, repair, and maintenance services for homes with UV air purifiers, air filters, and other indoor air quality systems. If you’re unsure as to the type of IAQ unit that could best serve your needs, then call us for a comfort consultation. We’ll test your indoor air quality and give you our professional opinion on the next steps to take, as well as answer all of your questions about this technology.
Water Heaters
Not every home can work with the same type of water heater. Some homes require an alternative approach, like the hyper-efficient tankless water heaters, or an indirect water heater. Tankless systems provide hot water without the use of a water tank, and indirect water heaters utilize the residual heat from your heating system to keep your water hot. Regardless of your personal preference, we’ll help you achieve energy savings today. We can find the perfect water heater solution for your needs!
We Go The Extra Mile With A Smile
Connect with our team today to get started on excellent service you'll love. Call 616-889-0112 now!
Recent Jobs and Reviews in Wyoming, MI
Customers say: The reviews exhibit a positive sentiment overall, with many customers expressing satisfaction with the services provided by GR Metro Heating and Cooling. The positive reviews frequently mention friendly and professional service, timely responses, and effective problem-solving. Customers appreciate the technicians' expertise, courtesy, and willingness to explain the work done. Additionally, the company is praised for its competitive pricing, punctuality, and cleanliness during the service. However, a few negative reviews are present, primarily focusing on issues with scheduling or communication. However, the negative reviews are outweighed by the positive feedback, indicating that the majority of customers have had positive experiences with GR Metro Heating and Cooling.
Our Local Reviews by City
- Ada, MI (3)
- Byron Center, MI (3)
- Caledonia, MI (3)
- Cedar Springs, MI (2)
- Comstock Park, MI (2)
- East Grand Rapids, MI (1)
- Georgetown Township, MI (1)
- Grand Haven, MI (1)
- Grand Rapids, MI (74)
- Grandville, MI (3)
- Howard City, MI (1)
- Hudsonville, MI (3)
- Kentwood, MI (1)
- Rockford, MI (3)
- Walker, MI (3)
- Wyoming, MI (6)
Job Locations and Reviews
We are out today because system was failing to heat. It was running when I arrived today. Client recently swapped the filter. Saved error code on the furnace was showing a high limit trip, due to overheating. Temperature rise is fine with new filter. I was able to find the old filter and put that in to test and the system heated up very fast and tripped limit. Very fine dust particles on filter, most likely from using portable humidifier. Recommend monthly filter checks. System is operating properly at this time. Might not be a bad idea to look into a whole home humidifier. Gave estimate for that. Thank you for having us out!
.
Tune up. Cleaned flame sensor, checked filter, checked igniter. Verified proper amperage’s and temperatures. Checked and cleared drains. Verified proper temp split. Verified proper operations of safeties. Everything working correctly at this time. Did notice system was missing surge protection. Provided option for surge protection. When duct fog solution is back in stock we will return and preform the duct fog and install surge protection at the same time
Installed power humidifier.
Customer was having problems with their brand new smart thermostat. Tried trouble shooting methods to figure out what was wrong with it and also recommended for us to install a simple thermostat instead and customer wanted that instead.
Club member tune up. System works correctly at this time. Did notice igniter to be worn and condensate pump to be making sounds while running which coincide with wear. Provided options. Customer went with options and after work was done everything
No heat. Noticed board failed and transformer failed. Also noticed no surge protection and graveling inducer. Suggested replacement of those parts. Customer declined repairs in hopes to research for better options. They will reach out when they are ready to move forward
7050 after rebate $6550 $97 month for ten year loan Estimated savings of $28 month
Performed heating system tuneup. Inducer motor and blower motor amp draws all within proper specification. Tested system safeties and ignition components. Pulled and cleaned flame sensor. Gas pressures and temperature rise are within range. Tested condensate trap and drainage system. Verified the safety and integrity of the heat exchanger. System is operating properly at this time and is in overall good condition. Humidifier supply valve is defective. I will return at a later date to replace that. Thank you for having us out!
Customer had us out for a concern over his furnace cycling more than usual. Upon inspection of the system I noticed the furnace to be working correctly. Customer informed me the thermostat is old. It is an eco bee. After messing with setting for the threshold i noticed the thermostat not reading the temperature correctly in the Home. I confirmed this via my thermometer. I provided options for new thermostats, customer said they will mess around with it and see if they can make it work. They will reach out when they are ready to move forward
No heat. Customer stated the furnace would click on and off many times when running. Upon inspection, i noticed the heat exchanger to be very clogged thus not allowing for proper ventilation of exhaust gas causing the system to overheat and when it cools down it will turn on again and keep doing the same thing. Due to clogged heat exchanger, the furnace is failing potential of carbon monoxide to leak into air stream in the near future Furnace is from 1987 and not parts are available, set up a time for install supervisor to stop out and give replacement options Customers going with option B 97% or c 96% submitting to insurance left portable heater follow up tmmr
No heat. Customer stated the furnace would click on and off many times when running. Upon inspection, i noticed the heat exchanger to be very clogged thus not allowing for proper ventilation of exhaust gas causing the system to overheat and when it cools down it will turn on again and keep doing the same thing. Due to clogged heat exchanger, there is a risk for failure of the furnace and potential of carbon monoxide to leak into air stream in the near future Furnace is from 1987 and not parts are available, set up a time for install supervisor to stop out and give replacement options.m
Performed heating system tuneup. Inducer motor and blower motor amp draws all within proper specification. Tested system safeties and ignition components. Pulled and cleaned flame sensor. Gas pressures and temperature rise are within range. Tested condensate trap and drainage system. Verified the safety and integrity of the heat exchanger. System is operating properly at this time and is in overall good condition. Thank you for having us out!
Performed heating system tuneup. Inducer motor and blower motor amp draws all within proper specification. Tested system safeties and ignition components. Pulled and cleaned flame sensor. Gas pressures and temperature rise are within range. Tested condensate trap and drainage system. Verified the safety and integrity of the heat exchanger. System is operating properly at this time and is in overall good condition. Thank you for having us out!
Installed Bradford White RG2PV75H6N power-vent water heater. Connected gas line using flexible connector. Installed new B-vent piping. Set gas pressure to 5" W.C. Adjusted thermostat to 120°F. Installed expansion tank. Tested TPR valve and verified proper venting with smoke test.
No heat in mobile home furnace. Clogged gas orifice from spider web, cleared and system functions properly
Installed new trap for furnace
Scheduled replacement for condensate trap
Loose safety wire blowing fuse while rubbing on blower motor shaft. Cut out old wiring and secured it. System works normal. Repair covered under warranty
No heat. Sticking gas valve and rusty safety switch. Quoted gas valve and switch.
I responded to a furnace not kicking on in Wyoming, MI. Upon inspection, I found a faulty igniter that was preventing the system from starting. I replaced the damaged igniter with a new OEM part and tested the furnace through a complete heating cycle. The system is now operating efficiently, and heat has been restored. I advised the homeowner on regular maintenance to prevent similar issues in the future.
Performed heating system tuneup. Inducer motor and blower motor amp draws all within proper specification. Tested system safeties and ignition components. Pulled and cleaned flame sensor. Gas pressures and temperature rise are within range. Tested condensate trap and drainage system. Verified the safety and integrity of the heat exchanger. System is operating properly at this time and is in overall good condition. Thank you for having us out!
Customer got unit replaced in June
Went over options with customer they like option b 92% furnace
Furnace and ac tune up. Furnace in good condition as well as ac. Suggested repairs and improvements Replaced rusted burner assembly